Free T4, FT4
24 hours
Electrochemiluminescence immunoassay (ECLIA)
Accredited NRL Laboratory
Daily
Free thyroxine (FT4) measures the unbound, biologically active fraction of thyroxine circulating in the blood (~0.02% of total T4) and is essential for evaluating secondary and central thyroid disorders, when TSH levels may be misleading.
Results are reported in SI Units (pmol/L)
Serum or Plasma
0.5 mL
Serum (SST; Gold Top or plain serum; Red Top) - Preferred Lithium Heparin Plasma (Green Top) - acceptable
High doses of Biotin (Vitamin B7) may potentially interfere with the results for this test. The effect of Biotin interference can be greatly reduced or eliminated if the sample is taken at least 8 hours following the last dose.
This test does not require any special collection or pre-analytical handling. Follow routine specimen collection protocols.
| Temperature | Period |
|---|---|
| Refrigerated | 7 days at 2-8°C |
| Frozen | 30 days at -20°C |