loader
Find a Test

Factor XI Activity With Inhibitor Reflex

Order Code
086302
CPT
To be determined. Updates will be made when available.
Test Details
Synonyms

Factor XI Inactivator; Factor XI Bethesda Titer

TAT

11 days

Methodology

See individual activity test information for method information.

Remarks

Special Instructions:
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions. Do not draw from an arm with a heparin lock or heparinized catheter.


Causes for Rejection:
Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability

Performing Location

Accredited Laboratory Partner

Testing Frequency

Contact Technical Support

Test Overview

This profile measures factor X activity and reflexes to a measurement of factor X inhibitor level (Bethesda titer) when the activity level is diminished to 40% or less.

Specimen Type

Plasma

Volume

2 mL

Specimen Container

Blue top (sodium citrate) tube

Patient Preparation

Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing.

Collection

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes.

Specimen Stability
Temperature Period
Frozen 28 days
Freeze/thaw cycles Stable x3
Order Code
086302
CPT
To be determined. Updates will be made when available.
Test Details
Synonyms

Factor XI Inactivator; Factor XI Bethesda Titer

TAT

11 days

Methodology

See individual activity test information for method information.

Remarks

Special Instructions:
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions. Do not draw from an arm with a heparin lock or heparinized catheter.


Causes for Rejection:
Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability

Performing Location

Accredited Laboratory Partner

Testing Frequency

Contact Technical Support

Test Overview

This profile measures factor X activity and reflexes to a measurement of factor X inhibitor level (Bethesda titer) when the activity level is diminished to 40% or less.

Specimen Type

Plasma

Volume

2 mL

Specimen Container

Blue top (sodium citrate) tube

Patient Preparation

Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing.

Collection

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes.

Specimen Stability
Temperature Period
Frozen 28 days
Freeze/thaw cycles Stable x3