loader
Find a Test

Aluminum

Order Code
071548
CPT
82108
Test Details
TAT

8 days

Methodology

Inductively coupled plasma/mass spectrometry (ICP/MS)

Remarks

Cause for Rejection: Royal blue-top tube not used in specimen collection

Performing Location

Accredited Laboratory Partner

Testing Frequency

Contact Technical Support

Test Overview

Measures aluminum in blood. Useful in monitoring exposure or toxicity, especially in dialysis patients.

Specimen Type

Serum or Plasma

Volume

7 mL

Specimen Container

Royal blue-top (EDTA) tube or royal blue-top without EDTA

Patient Preparation

No special preparation is required for this test. You may eat, drink, and take your medications as normal, unless instructed otherwise by your healthcare provider.

Collection

Separate Serum or Plasma immediately after the collection, and transfer to a certified metal-free transport tube

Specimen Stability
Temperature Period
Room temperature 14 days
Refrigerated 14 days
Frozen 14 days
Order Code
071548
CPT
82108
Test Details
TAT

8 days

Methodology

Inductively coupled plasma/mass spectrometry (ICP/MS)

Remarks

Cause for Rejection: Royal blue-top tube not used in specimen collection

Performing Location

Accredited Laboratory Partner

Testing Frequency

Contact Technical Support

Test Overview

Measures aluminum in blood. Useful in monitoring exposure or toxicity, especially in dialysis patients.

Specimen Type

Serum or Plasma

Volume

7 mL

Specimen Container

Royal blue-top (EDTA) tube or royal blue-top without EDTA

Patient Preparation

No special preparation is required for this test. You may eat, drink, and take your medications as normal, unless instructed otherwise by your healthcare provider.

Collection

Separate Serum or Plasma immediately after the collection, and transfer to a certified metal-free transport tube

Specimen Stability
Temperature Period
Room temperature 14 days
Refrigerated 14 days
Frozen 14 days